Technical Document and Company News

Tecnica

How Do VLF Withstand, Tan Delta, Partial Discharge and Insulation Resistance Tests Differ?

VLF withstand, tan delta, partial discharge and insulation resistance tests examine different aspects of a cable system. Withstand assesses survival of specified electrical stress; tan delta measures overall dielectric-loss behavior; PD examines detected localized discharge activity; insulation resistance evaluates a defined DC response. Select them for complementary questions. A favorable result from one method does not automatically replace another required measurement or cancel a valid concern from a different method.

Leggi di più »
Uncategorized

What Does a Transformer Turns Ratio Tester Measure, and Which Faults Can It Miss?

A turns ratio tester assesses transformation behavior under defined test conditions; it does not certify the entire transformer. Verify the ratio definition, tap basis, connections, and measurement validity before interpreting a deviation. Use satisfactory results within their documented scope, and select complementary evidence when the question concerns insulation, contacts, mechanical condition, or an unexplained service event.

Leggi di più »
Tecnica

What Does an Industrial Battery Discharger Actually Measure?

An industrial battery discharger applies a specified load and records current, voltage, time, and sometimes temperature and individual cell voltages. It measures delivered charge or energy to an agreed endpoint. Conductance and impedance tests provide condition indicators, but do not directly establish usable discharge capacity.

Leggi di più »
Tecnica

What Does an Industrial Battery Discharger Actually Measure?

An industrial battery discharger applies a specified load and records current, voltage, time, and sometimes temperature and individual cell voltages. It measures delivered charge or energy to an agreed endpoint. Conductance and impedance tests provide condition indicators, but do not directly establish usable discharge capacity.

Leggi di più »
Società New

Attrezzatura di test per trasformatori KV Hipot applicata nel progetto di stoccaggio dell’energia

I tester di resistenza trifase DC (20A) e i tester di rapporto di torsione trifase di KV Hipot Power Equipment Co., Ltd. sono stati utilizzati per le prove elettriche del trasformatore principale nella sottostazione di conversione a 220 kV, supportando la misurazione della resistenza dei fili e la verifica del rapporto di torsione durante la fase di messa in servizio in loco.

Leggi di più »
Tecnica

Cos’è un tester VLF Tan Delta e cosa può dirci sull’isolamento dei cavi?

A VLF tan delta tester provides system-level dielectric-loss evidence. Use it to establish documented behavior, compare genuinely comparable records, and direct further investigation when the evidence warrants it. Before accepting a conclusion, verify the measurement boundary, the equipment’s supported conditions, and the interpretation basis. The most useful outcome is a justified next action for the identified circuit, with a clear statement of what the test has and has not established.

Leggi di più »
Tecnica

Quali specifiche tecniche determinano le prestazioni di un tester VLF Hipot?

Evaluating a VLF hipot tester requires prioritizing continuous capacitive load capability (µF at 0.1 Hz) over mere open-circuit test voltage. Match your required IEEE 400.2 withstand levels with pure sinusoidal waveform purity, fine current resolution, automatic frequency adaptation, and fail-safe discharge systems. Before purchasing, verify manufacturer load-derating curves against your longest installed cable circuits to guarantee reliable field performance.

Leggi di più »