Technical Document and Company News

Tehnică

What Does an Industrial Battery Discharger Actually Measure?

An industrial battery discharger applies a specified load and records current, voltage, time, and sometimes temperature and individual cell voltages. It measures delivered charge or energy to an agreed endpoint. Conductance and impedance tests provide condition indicators, but do not directly establish usable discharge capacity.

Read More »
Tehnică

Ce este un tester VLF Tan Delta și ce vă poate spune acesta despre izolarea cablului?

A VLF tan delta tester provides system-level dielectric-loss evidence. Use it to establish documented behavior, compare genuinely comparable records, and direct further investigation when the evidence warrants it. Before accepting a conclusion, verify the measurement boundary, the equipment’s supported conditions, and the interpretation basis. The most useful outcome is a justified next action for the identified circuit, with a clear statement of what the test has and has not established.

Read More »
Tehnică

Care sunt specificațiile tehnice care determină performanța unui tester VLF Hipot?

Evaluating a VLF hipot tester requires prioritizing continuous capacitive load capability (µF at 0.1 Hz) over mere open-circuit test voltage. Match your required IEEE 400.2 withstand levels with pure sinusoidal waveform purity, fine current resolution, automatic frequency adaptation, and fail-safe discharge systems. Before purchasing, verify manufacturer load-derating curves against your longest installed cable circuits to guarantee reliable field performance.

Read More »
Noutăți despre companie

What VLF Hipot Test Voltage Should You Use for a 33 kV Cable?

There is no universal test voltage for every 33 kV cable. If the nameplate is 19/33 (36) kV and the approved procedure specifies 3U₀ sinusoidal VLF, the calculated level is 57 kV RMS, or approximately 81 kV peak. An 18/30 (36) kV cable would produce a different result.

Read More »
Tehnică

Troubleshooting Guide for 33kV Cable Hipot Test Voltage Drops?

Troubleshooting voltage drops during a 33kV cable hipot test requires a clear understanding of capacitive loads, proper grounding, and insulation behavior. By lowering your VLF frequency to manage capacitance, resolving ground loops, and recognizing the signs of partial discharge, you can maintain stable test voltages.

Read More »
Tehnică

What Are the Key Technical Specifications of a Sweep Frequency Response Analyzer?

A suitable SFRA analyzer should provide adequate frequency coverage, measurement span, repeatable connections, controlled impedance, traceable output settings, and practical test time. For the KVRZ-S, the manual specifies 10 Hz–10 MHz linear sweep capability, a −120 dB to +20 dB amplitude range, 50 Ω output impedance, and less than 60 seconds per phase.

Read More »

Solicitare Acum