Technical Document and Company News

Técnica

Which Technical Specifications Determine the Performance of a VLF Hipot Tester?

Evaluating a VLF hipot tester requires prioritizing continuous capacitive load capability (µF at 0.1 Hz) over mere open-circuit test voltage. Match your required IEEE 400.2 withstand levels with pure sinusoidal waveform purity, fine current resolution, automatic frequency adaptation, and fail-safe discharge systems. Before purchasing, verify manufacturer load-derating curves against your longest installed cable circuits to guarantee reliable field performance.

Read More »
Técnica

Troubleshooting Guide for 33kV Cable Hipot Test Voltage Drops?

Troubleshooting voltage drops during a 33kV cable hipot test requires a clear understanding of capacitive loads, proper grounding, and insulation behavior. By lowering your VLF frequency to manage capacitance, resolving ground loops, and recognizing the signs of partial discharge, you can maintain stable test voltages.

Read More »
Técnica

What Are the Key Technical Specifications of a Sweep Frequency Response Analyzer?

A suitable SFRA analyzer should provide adequate frequency coverage, measurement span, repeatable connections, controlled impedance, traceable output settings, and practical test time. For the KVRZ-S, the manual specifies 10 Hz–10 MHz linear sweep capability, a −120 dB to +20 dB amplitude range, 50 Ω output impedance, and less than 60 seconds per phase.

Read More »
Técnica

What Is the BDV of Oil in a 33 kV Transformer?

An Oil BDV Tester provides a fast and valuable indication of an insulating liquid’s ability to withstand electrical stress under a defined test method. The reliability of that indication depends on much more than the maximum tester voltage.

Read More »
Técnica

VLF Cable Testing Applications by Industry

Utilities use planned VLF withstand or diagnostic work to support acceptance, maintenance prioritization, and investigation of shielded distribution circuits. Equipment selection and interpretation must also account for cable voltage, capacitance, waveform, condition, and the approved procedure.

Read More »
Battery pack in battery room in power plant for supply electricity in plant during shutdown phase
Técnica

What is a battery discharge tester used for?

A battery discharge tester is an electronic load device used to measure the true capacity of backup batteries. It pulls a constant current from the battery until a cutoff voltage. This test finds dead cells and proves the battery can support your critical systems during a real power outage.

Read More »

Consulta Ahora