Technical Document and Company News

เทคนิค

How Do VLF Withstand, Tan Delta, Partial Discharge and Insulation Resistance Tests Differ?

VLF withstand, tan delta, partial discharge and insulation resistance tests examine different aspects of a cable system. Withstand assesses survival of specified electrical stress; tan delta measures overall dielectric-loss behavior; PD examines detected localized discharge activity; insulation resistance evaluates a defined DC response. Select them for complementary questions. A favorable result from one method does not automatically replace another required measurement or cancel a valid concern from a different method.

อ่านเพิ่มเติม »
Uncategorized

What Does a Transformer Turns Ratio Tester Measure, and Which Faults Can It Miss?

A turns ratio tester assesses transformation behavior under defined test conditions; it does not certify the entire transformer. Verify the ratio definition, tap basis, connections, and measurement validity before interpreting a deviation. Use satisfactory results within their documented scope, and select complementary evidence when the question concerns insulation, contacts, mechanical condition, or an unexplained service event.

อ่านเพิ่มเติม »
Company New

Main Transformer and Switchgear Field Testing at the PV Project’s 220 kV Step-Up Substation

KV Hipot Power Equipment Co., Ltd. provides transformer testing, circuit breaker testing and high-voltage electrical test equipment for PV projects, electrical contractors and substation commissioning teams. Contact KV Hipot to discuss instrument selection and configurations based on your assets, test requirements and site power supply.

อ่านเพิ่มเติม »
เทคนิค

Pre-Commissioning vs Commissioning: Electrical Tests, Acceptance Criteria, and Energization Readiness

Electrical pre-commissioning verifies that installed equipment is ready for the next approved testing or energization stage. Commissioning verifies that the equipment and interconnected systems perform their intended functions. Commissioning includes activities before energization, during controlled energization, and under operating conditions.

อ่านเพิ่มเติม »
Company New

อุปกรณ์ทดสอบหม้อแปลง KV Hipot ใช้ในโครงการจัดเก็บพลังงาน

KV Hipot Power Equipment Co., Ltd.’s three-phase DC resistance tester (20A) and three-phase turns ratio tester were used for electrical testing of the main transformer at the 220 kV step-up substation, supporting winding resistance measurement and turns ratio verification during the on-site commissioning phase.

อ่านเพิ่มเติม »
เทคนิค

VLF Tan Delta Tester คืออะไร และสามารถบอกอะไรเกี่ยวกับฉนวนของสายไฟได้บ้าง

A VLF tan delta tester provides system-level dielectric-loss evidence. Use it to establish documented behavior, compare genuinely comparable records, and direct further investigation when the evidence warrants it. Before accepting a conclusion, verify the measurement boundary, the equipment’s supported conditions, and the interpretation basis. The most useful outcome is a justified next action for the identified circuit, with a clear statement of what the test has and has not established.

อ่านเพิ่มเติม »
เทคนิค

คุณสมบัติทางเทคนิคใดที่กำหนดประสิทธิภาพของเครื่องทดสอบ VLF Hipot?

Evaluating a VLF hipot tester requires prioritizing continuous capacitive load capability (µF at 0.1 Hz) over mere open-circuit test voltage. Match your required IEEE 400.2 withstand levels with pure sinusoidal waveform purity, fine current resolution, automatic frequency adaptation, and fail-safe discharge systems. Before purchasing, verify manufacturer load-derating curves against your longest installed cable circuits to guarantee reliable field performance.

อ่านเพิ่มเติม »

สอบถามตอนนี้