Descrição
Overview
KV-6000A Transformer Capacitance Tan-delta Tester is a automatic on-site tester that is designed to measure dielectric loss(tgδ)and the capacitance (Cx) of electric equipment. The measure result can be displayed on the LCD screen and printed by micro-printer .It’s suitable for testing on transformer, capacitor, insulating bush, CT/PT, MOA .
Features
- The instrument adopts complex number current method to measure capacitance, dielectric loss and other parameters. The measured result is highly accurate and it is easy to realize automatic measurement.
- The instrument adopts variable frequency technology to eliminate 50Hz/60Hz power frequency interference. The measurement data will be get even under the strong electromagnetic interference.
- The instrument is easy to operate and the measuring process is controlled by microprocessor. Once a suitable measuring method is selected, the data measurement will complete automatically under the control of microprocessor.
- The instrument is designed to be an integrated model with reference capacitor and HV power supply in it, enables site test measurement and reduces site wiring.
- The instrument is equipped with CVT testing function, which can achieve CVT self-exciting testing without external accessories and measure the capacitance and dielectric loss of C1 and C2 by at a time.
- GST measurement adopts ivddv technology to avoid unstable data provided by previous GST measurement.
- The instrument provides low voltage shell function of GST. When the bus of 220kV CVT is grounded, dielectric loss measurement can be conducted for C11 without removing 10 kV GST.
- The instrument has a function of measuring high-voltage dielectric loss. It can carry out dielectric loss test with over 10kV with the help of voltage transformer or series resonance.
- The instrument has a ground-fault protection function. If the instrument is not grounded or grounded incorrectly, the instrument will refuse to enter into normal procedure and output HV.It has the over-current protection function, which can protect the instrument from damage when the test object is in a short circuit or breakdowns.
- The instrument has a function of electric shock protection. When the instrument operator suffers an electric shock because of error operation , the instrument will cut off the HV immediately to ensure the security of operator.
Technical parameter
♦ Accuracy: Cx: ±(read ×1%+1pF)
tgδ: ±(read ×1%+0.00040)
♦ Anti interference: Frequency conversion anti interference, under 200% interference, still can reach above accuracy.
♦ Capacitance range:Inner HV: 3pF~60000pF/10kV 60pF~1μF/0.5kV
Outside HV: 3pF~1.5μF/10kV 60pF~30μF/0.5kV
Resolution: Max. 0.001pF,4 significant figures
♦ Tgδ range: unlimited, resolution: 0.001%, capacitance, inductance, resistance can be identify automatically.
♦ Test current range: 10μA~1A
♦ Inner HV:Setting voltage range: 0.5~10kV
Max.Output current: 200mA
Increase/decrease voltage: continuous slide regulating.
Test frequency: 45, 50, 55 single frequency
45/55Hz auto double frequency conversion
Frequency precision: ±0.01Hz
♦ Outside HV: Positive connection max. test current 1A, Power frequency or frequency conversion 40-70Hz
Negative connection max. test current: 10kV/1A, power frequency or frequency conversion 40-70Hz
♦ CVT self excitation LV output: voltage 3~50V,current 3~30A
♦ Measuring duty: about 30s,it depend on measuring methods.
♦ Input power supply: 180V~270VAC,50Hz±1%,local supply or by generator.
♦ Communication interface: RS232.
♦ Printer: Build-in thermal printer.
♦ Environmental temperature: -10℃~50℃
♦ Relative humidity: <90%
♦ Oversize: 463×362×350mm
♦ Weight: 29kg