VLF Cable Tester

Hipot Cable Testing and Analysis

Precisely detect hidden faults in cables and high-voltage equipment, extend equipment lifespan, and ensure safe and stable operation of your power system

With the rapid development of the power industry, power cables play a crucial role in the stability and safety of running power systems.  The demand for cable testing equipment is steadily increasing. VLF(Very Low Frequency) cable  tester is a specialized instrument designed to assess the insulation performance of power cables, motor windings, and high-voltage equipment. By operating at low frequencies, it can effectively detect defects that may not be easily identified with high-frequency signals, making it essential for the maintenance and fault detection of power systems.

 

Hipot Cable Tester

Hipot Cable Tester  is  used to verify the integrity of the insulation in medium and high voltage (MV and HV) cables. This technique is particularly advantageous for field testing due to the portability of VLF equipment, which is typically smaller and lighter compared to traditional high-frequency test equipment. The inherent capacitance of power cables requires charging when energized, and since VLF systems operate at frequencies below 1 Hz, they consume significantly less power than systems using higher frequencies. This makes VLF testing an efficient and cost-effective approach, especially for testing modern polymer-insulated cables such as XLPE and EPR.

Testador de VLF
Portable Hipot Test for Cable
Probador Hipot de muy baja frecuencia (VLF)
Hipot cable tester 01
High Voltage Cable Tester

Cable Tan Delta Test

During long-term operation, power cables may experience insulation aging, damage, and other issues due to various factors. These problems can lead to dielectric loss, which affects the normal functioning of the cable.  The dielectric loss testing in power cables is essential.

VLF cable tan delta tester is an effective and reliable test equipment for measuring the dielectric loss factor, or Tan Delta, of high-voltage cables. It operates by applying a low-frequency AC voltage to the cable and measuring the phase angle difference between the induced current and the voltage, which is then used to calculate the dielectric loss factor.

VLF Tan Delta Tester
Probador Hipot de muy baja frecuencia (VLF)

Advanced VLF tester by application

VLF testers are widely used in power transmission and distribution networks for testing medium- and high-voltage cables, ensuring grid reliability and safe operation. They play a crucial role in renewable energy systems, industrial plants, electrical system and transportation networks like railways and subways by verifying the insulation integrity of critical infrastructure. Additionally, they are essential in factory testing for cable manufacturers and maintaining underground cables in airports, mining, and utilities

Power Transmission
Electrical System
Power Substation
Energy
Power Plant
Cable Factory

SOLICITE UN PRESUPUESTO PARA MÁS DETALLES

Detalles del producto

Wanna dig deeper in high voltage cable tester for your project ?

There are professional product technical details in this catalog, you can leave us you email here and our experienced engineer will contact with you within 24 hours.
CALIENTE

What is the standard of vlf tester ?

IEEE 400.2-2013 standard provides a guide for field testing of shielded power cable systems using VLF and is particularly useful for diagnosing various cable insulation problems. It suggests that VLF testing should last between 15 and 60 minutes, with a recommended minimum duration of 30 minutes, and that the tested cable must withstand the AC voltage for the specified time without flashover. VLF testing can use different wave shapes, such as sine and square, and it is important to note that RMS and peak voltages have different relationships depending on the wave shape. IEEE 400.2 uses the peak voltage level to equate the wave shapes. The standard also embraces VLF testing as a viable alternative to DC testing, as it exposes serious cable defects without harming healthy insulation or aggravating minor defects. IEC 60502-2:2014 specifies the construction, dimensions, and test requirements for power cables with extruded solid insulation from 6 kV up to 30 kV for fixed installations. It includes a new subclause for a routine electrical test on the oversheath and the inclusion of a 0.1 Hz test after installation, which is relevant for VLF testing.

¿Por qué la gente utiliza el verificador de hipotensión VLF?

Los comprobadores hipotrónicos VLF utilizan una salida de voltaje en forma de onda sinusoidal que suele oscilar entre 0,1 Hz y 0,01 Hz. La frecuencia de la salida VLF es importante porque afecta al nivel de tensión de prueba que se puede aplicar a la aislación sin causar daños. En frecuencias más bajas, se pueden aplicar tensiones más altas sin dañar la aislación. Esto se debe a que la baja frecuencia permite que la tensión penetre en la aislación y cargue la capacitancia del sistema, en lugar de causar simplemente una ruptura superficial.

What is the principle of vlf hipot tester

VLF testing adopts generate AC voltage with the accuracy very low frequency signal and high output power . The output voltage of a VLF generator is passed through an insulation load connected to the cable to be tested. The insulation load is a highly capacitive load which simulates the properties of the cable insulation material. Measure the current and voltage of cable conduct and insulation material and analyze the abnormal voltage and current waveform to check the cable insulation and potential faults.

For a 33kV cable, the test voltage is typically set to 2.5–3 times the system voltage, i.e., between 57 kV and 76 kV (peak values) for the withstand test. This voltage is applied for the specified duration, usually between 15 to 60 minutes

VLF hipot cable tester ensures safety with built-in overvoltage and overcurrent protection  features that promptly disconnect power in abnormal conditions by urgent stop button. It is designed with clear operational guidelines and safety warnings to prevent accidents due to incorrect use. Additionally, the equipment maintains stability during operation to avoid safety issues caused by malfunctions or unstable performance

Conocimiento técnico del producto

why do you choose us ?

Nuestra ventaja

Empleado de la computadora

Nuestras ventajas en I+D incluyen un equipo altamente cualificado que aprovecha tecnologías de medición avanzadas e incorpora los comentarios de los clientes para garantizar que nuestros productos satisfagan las necesidades del mercado. Además, realizamos pruebas rigurosas y mantenemos colaboraciones con universidades e instituciones de investigación para impulsar la innovación y la optimización constantes.

VLF Tester VLF-80_

utilizando tecnología de medición avanzada para garantizar datos de alta precisión. El diseño se enfoca en un rendimiento constante durante el funcionamiento a largo plazo en diversas condiciones ambientales. Además, su fuerte compatibilidad permite una integración perfecta con múltiples estándares industriales y dispositivos eléctricos, atendiendo a las diversas necesidades de los clientes.

VLF-Hipot-Testing

Los técnicos expertos son electricistas altamente experimentados y licenciados, así como expertos. Nuestro equipo ofrecerá una solución integral y apoyo técnico cuando elija equipos y inicie la puesta en marcha en el campo para el mantenimiento preventivo diario y el servicio de aceptación.

Subestación de alta tensión. Transformador de potencia. Subestación de distribución eléctrica

Our equipment offers a one-stop customized solution, providing unparalleled versatility for testing various objects such as MV/LV cables, rotating motor and generator coils, power capacitor and transformers. It supports diverse testing scenarios and includes integrated data acquisition software for precise real-time insights and comprehensive reporting.

¡Contáctenos hoy mismo!

Podemos ofrecer un servicio excepcional y apoyo técnico para resolver sus problemas de pruebas eléctricas.

Consulta Ahora