Product

How to Work with Us ?

To get started, please share the detailed specifications of your requirements. Our professional sales engineers are available 24/7 to assist you with any questions. Feel free to reach out to us via email, phone, or by visiting us in person.

Frequently asked questions

We are professional test equipment manufacturers which have our own R&D team, production workshop, quality control system and marketing depart

We offer 12 months warranty and lifelong maintenance. The warranty applies to the original purchaser that the equipment will be free of any defect in materials or workmanship for a period of one year from the date of purchase. The warranties only cover defects arising under normal use and regular service, excluding any faults and damages resulting from abuse misuse, alteration, improper installation, neglect or adverse environmental condition, not from quality problem.

Normally the delivery time is about 15 working days after payment. For some special customized products, it will takes 15 – 30 working days depending on technical parameter of customer requirement.

Contact Us

Email: info@kvhipot.com
TEL: +86 18062060691
WhatsApp: +8618062060691

OR

 SFRA Tester Sweep Frequency Response Analyzer KVRZ-S

SFRA analyzer will quantify the response changes of internal winding parameters in different frequency domains, and then determine the degree of change of internal windings according to the variables, the amplitude of frequency response change, the area and the trend of frequency response change. Thus, it can judge whether the transformer has been severely damaged and needs to be overhauled according to the measurement results.

Products Details

yehgyeygbvh

 

euytyekcytyheybhf

Descripción

KVRZ-S  SFRA Sweep Frequency Response Analyzer

SFRA analyzer will quantify the response changes of internal winding parameters in different frequency domains, and then determine the degree of change of internal windings according to the variables, the amplitude of frequency response change, the area and the trend of frequency response change. Thus, it can judge whether the transformer has been severely damaged and needs to be overhauled according to the measurement results.

Features

  • USB communication interface facilitates seamless connectivity between the laptop and the instrument.
  • Control and data acquisition are executed through a high-speed, highly integrated microprocessor.
  • The hardware integrates dedicated DDS digital high-speed scanning technology (from the USA), enabling precise fault diagnosis, including winding distortion, bulging, shifting, tilting, inter-turn short-circuit deformations, and inter-phase contact short-circuits.
  • Utilizes high-speed dual-channel 16-bit A/D sampling, effectively capturing significant waveform changes during field tests, tap changer operations, etc.
  • Signal output amplitude is software-adjustable, with a peak range of ±
  • Automated analysis of test results and generation of electronic documents (Word format) by the computer.
  • Equipped with dual measurement capabilities: linear frequency scanning and segment frequency scanning, conforming to the measurement standards of two technical groups in China.
  • Amplitude-frequency characteristics adhere to national technical specifications for amplitude-frequency characteristic testers. The X-coordinate (frequency) offers both linear and logarithmic indexing options, facilitating curve printing based on user preference and requirements.
  • Features an automatic test data analysis system

 

 

Technical parameter

Scan mode:

  1. Linear scanning distribution

Scanning measurement range: (10Hz) – (10MHz) 40000 scanning point, resolution 0.25kHz, 0.5kHz and 1kHz.

  1. Segment sweep frequency measurement distribution

Sweep frequency measurement range: (0.5kHz) – (1MHz), 2000 scanning points ;

(0.5kHz) – (10kHz)

(10kHz) – (100kHz)

(100kHz) – (500kHz)

(500kHz) – (1000kHz)

 

Other technical parameters:

 

Amplitude measurement range (-120dB) -(+20dB)
Amplitude measurement accuracy 0.1dB
Accuracy of sweep frequency 0.005%
Signal input impedance 1MΩ
Signal output impedance 50Ω
Signal output amplitude ±20V
In-phase test repetition rate 99.9%
Dimension of measuring instrument (Length, width and height): 370X310X175(mm)
Dimension of aluminum alloy cable box (Length, width and height): 420X300X320(mm)
Total weight 20Kg
Operating temperature -10℃- +40℃
Storage temperature -20℃- +70℃;
Relative humidity <90%, noncondensing

 

 