Technical Document and Company News

Nezařazené

A comprehensive analysis of troubleshooting and treatment of power transformers

This article provides a comprehensive analysis and study of fault diagnosis and treatment of power transformers. Through a detailed discussion of fault types and causes, we identify major fault types such as overheating faults in conducting circuits, degradation of insulation levels, gas-producing faults, regulator switch faults, transformer winding deformation, transformer oil seepage defects, and capacitor bushing faults, and analyze their impact on the safe operation of the transformer

Read More »
Nezařazené

10kV High Voltage Power Equipment Preventive Maintenance

High voltage switchgear, Current transformer and voltage transformer, circuit breakers, busbars, transformers, 10kV cables, switchgear, lightning arresters, grounding systems, relay protection devices, and 10kV high voltage busbar tests are all common components in power systems. Regular preventive testing is essential to ensure the safe operation of this equipment. Next, we will discuss the preventive power tests for these common components.

Read More »
Vysokonapěťová elektrická vedení
Technika

Jak změřit izolační odpor kabelu?

Abychom splnili provozní požadavky energetické soustavy, musíme klást důraz na izolační vlastnosti a provádět izolační zkoušky. Před uvedením do provozu nebo při dokončení návrhu výrobku je nutné použít standardní zkušební metody, aby bylo zajištěno, že izolační vlastnosti vodičů a kabelů splňují konstrukční a provozní požadavky.

Read More »
Stručný přehled
Technika

Jak testovat vysokonapěťový rozvaděč?

Prostřednictvím zkušebního testu pro elektrické zkoušení vysokonapěťových rozvaděčů lze komplexně zkontrolovat výkonnostní parametry zařízení, a to včas zjistit případné nedostatky a skryté nebezpečí, aby bylo zajištěno, že zařízení bude po uvedení do provozu stabilně a spolehlivě fungovat.

Read More »
Technika

What Are the Best Voltage Withstand Test Methods for Power Cables?

This article mainly discusses the test methods of oil-impregnated paper-insulated cables, plastic-insulated cables and cross-linked polyethylene cables, and the common electrical tests include DC withstand voltage and leakage current tests, VLF withstand voltage tests, Power frequency AC resonance withstand voltage testing , partial discharge tests and so on.

Read More »
Rozvodna s vysokonapěťovým výkonovým transformátorem.
Technika

What is rated power frequency withstand voltage?

Rated frequency withstand voltage is the maximum voltage that electrical equipment or its insulation system can safely handle during normal operation at the rated frequency (such as 50Hz or 60Hz). Under this voltage, the equipment can operate normally without experiencing insulation breakdown or other failures.

Read More »
Technika

What is the difference between transformer “Type testing”and “Factory acceptance testing”(FAT)?

we will analyze the differences between transformer type testing and transformer factory acceptance testing in terms of standard basis, test items, parameter requirements, and criteria for passing judgment. This analysis aims to provide valuable references and guidelines for the design, manufacture, acceptance, operation, and maintenance of transformers.

Read More »
Technika

What is battery charger discharger ?

A battery charger discharger is an advanced piece of equipment designed to perform two critical tasks: charging a battery to its full capacity and discharging it to measure performance, capacity, and other key parameters. These systems are commonly used for testing and maintaining batteries in various applications, ensuring their optimal operation and longevity.

Read More »
Technika

How Battery Test Equipment Supports the Power Systems

Battery test equipment is essential for maintaining the reliability and performance of batteries in backup power systems. These tools play a crucial role in ensuring that batteries function as expected during critical moments and remain in optimal condition throughout their lifecycle.

Read More »
Technika

BDV test of transformer oil

The dielectric strength test for transformer insulating oil is an electrical performance evaluation defined as the measurement of the maximum voltage that the oil can withstand between two electrodes under specified test conditions before electrical breakdown occurs

Read More »