Technical Document and Company News

High voltage power transformer substation.
Texnika

Why test high voltage circuit breakers?

Regular preventive testing of high-voltage circuit breakers, including insulation resistance, dielectric loss factor, contact resistance, AC withstand voltage, vacuum level, mechanical characteristics, primary current injection, SF6 gas quality, and insulating oil tests, is essential to ensure their safety, reliability, and operational integrity, preventing faults that could compromise the power system.

Read More »
Tegoriklanmagan

How AC Resonance Testing Enhances GIS Reliability and Longevity

AC resonance test system helps extend the lifespan of GIS components, allowing operators to maximize the return on investment in this critical electrical infrastructure. By incorporating resonance testing into their maintenance strategies, utilities and industrial operators can significantly improve the operational efficiency and durability of their GIS systems.

Read More »
Texnika

What is battery discharge tester ?

A battery converts chemical energy into electrical energy by creating a potential difference between two electrodes (anode and cathode) through a chemical reaction.

When a battery is discharged, electrons flow from the anode to the cathode while ions in the electrolyte move to maintain charge balance; when it is charged, the process is reversed.

Read More »
Tegoriklanmagan

Vacuum switch vacuum degree tester

Vacuum switch vacuum degree tester utilizes an innovative excitation coil and employs the magnetron discharge method to evaluate the vacuum degree of the arc extinguishing chamber without requiring disassembly.

Read More »
Tegoriklanmagan

What is the difference between tan delta test and megger test?

Tan delta testing, also known as dissipation factor (PF) testing, or loss angle testing or dielectric dissipation factor(DDF) , is a diagnostic method used to measure dielectric loss/dissipation factor(tgδ) and capacitance (Cx) and evaluate the insulation condition of electrical equipment, such as cables, transformers, capacitors, and rotating machines.

Read More »
Texnika

SFRA testi nima?

Sweep Frequency Response Analysis (SFRA) testi – bu elektr transformatorlarning mexanik va elektr barqarorligini baholash uchun qo‘llaniladigan muhim o‘lchov usulidir. Ushbu test transformator yadrolarining, o‘ralarining va press ramkalarning mexanik barqarorligini keng chastotali diapazon bo‘ylab kuchlanish uzatish funksiyasini o‘lchash orqali tekshiradi. Har bir elektr tarmoqining o‘ziga xos chastotali javobi – chastotali javob barmoq izi deb ataladi.

Read More »
Texnika

How to analyse transformer oil ?

There are some tests for insulation oil testing include Breakdown voltage (BDV)test, water content test, acidity test, Dielectric Dissipation Factor test, Interfacial Tension test, Flash Point test, Viscosity test, Relative Density Test, Furan Analysis , Dissolved Gas Analysis (DGA)ect.

Read More »