{"id":6420,"date":"2026-04-09T15:20:05","date_gmt":"2026-04-09T07:20:05","guid":{"rendered":"https:\/\/kvhipot.com\/?p=6420"},"modified":"2026-04-09T15:20:07","modified_gmt":"2026-04-09T07:20:07","slug":"co-je-to-testovanie-kablov-vlf","status":"publish","type":"post","link":"https:\/\/kvhipot.com\/sk\/what-is-vlf-cable-testing\/","title":{"rendered":"\u010co je to testovanie VLF k\u00e1blov?"},"content":{"rendered":"<h1 class=\"wp-block-heading\"><\/h1><p>Poruchy k\u00e1blov sp\u00f4sobuj\u00fa rozsiahle v\u00fdpadky elektrickej energie a nespokojnos\u0165 z\u00e1kazn\u00edkov. Odhalenie skryt\u00fdch z\u00e1vad pred zapnut\u00edm nap\u00e1jania je n\u00e1ro\u010dn\u00e9. Testovanie k\u00e1blov met\u00f3dou VLF tento probl\u00e9m rie\u0161i bezpe\u010dne a jednoducho.&nbsp;<strong>Pri testovan\u00ed k\u00e1blov met\u00f3dou VLF sa na kontrolu izol\u00e1cie stredonap\u00e4\u0165ov\u00fdch a vysokonap\u00e4\u0165ov\u00fdch k\u00e1blov pou\u017e\u00edva striedav\u00e9 nap\u00e4tie s ve\u013emi n\u00edzkou frekvenciou (0,1 Hz). T\u00e1to met\u00f3da odha\u013euje slab\u00e9 miesta v k\u00e1bloch s izol\u00e1ciou z XLPE bez toho, aby ich po\u0161kodila. Nahradzuje tak star\u00e9 testovanie jednosmern\u00fdm pr\u00fadom a zabezpe\u010duje bezpe\u010dnos\u0165 va\u0161ej elektrickej siete e\u0161te pred jej pln\u00fdm sprev\u00e1dzkovan\u00edm.<\/strong>&nbsp;Ka\u017ed\u00fd de\u0148 komunikujem s dod\u00e1vate\u013emi EPC. V\u017edy sa ob\u00e1vaj\u00fa testovania k\u00e1blov. Chc\u00fa vedie\u0165, \u010di tento test nepo\u0161kod\u00ed ich \u00faplne nov\u00e9 k\u00e1ble. P\u00fdtaj\u00fa sa ma, \u010di nejde len o \u010fal\u0161\u00ed zbyto\u010dn\u00fd krok. Pozrime sa na skuto\u010dn\u00e9 fakty t\u00fdkaj\u00face sa tejto testovacej met\u00f3dy.<\/p><h2 class=\"wp-block-heading\">Je testovanie k\u00e1blov met\u00f3dou VLF de\u0161trukt\u00edvne?<\/h2><p>Testovanie nov\u00fdch k\u00e1blov pod vysok\u00fdm nap\u00e4t\u00edm mnoh\u00fdch in\u017einierov des\u00ed. Po\u0161kodenie funk\u010dn\u00e9ho k\u00e1bla po\u010das testovania znamen\u00e1 stratu \u010dasu a pe\u0148az\u00ed. Testovanie met\u00f3dou VLF je ve\u013emi bezpe\u010dn\u00e9 a zabra\u0148uje neo\u010dak\u00e1van\u00fdm po\u017eiarom.\u00a0<strong>Testovanie k\u00e1blov met\u00f3dou VLF je nedestrukt\u00edvna sk\u00fa\u0161ka ur\u010den\u00e1 na kontrolu stavu k\u00e1blov. Po\u0161kod\u00ed iba tie k\u00e1ble, ktor\u00e9 u\u017e vykazuj\u00fa z\u00e1va\u017en\u00e9 poruchy izol\u00e1cie. Ak je v\u00e1\u0161 k\u00e1bel v poriadku, n\u00edzkofrekven\u010dn\u00fd test mu nijako neubl\u00ed\u017ei. Zabezpe\u010d\u00ed, \u017ee v\u00e1\u0161 k\u00e1bel vydr\u017e\u00ed po cel\u00fa dobu svojej \u017eivotnosti.<\/strong>\u00a0! <\/p><p>Mnoho \u013eud\u00ed sa ma p\u00fdta, \u010di testovanie VLF po\u0161kod\u00ed ich drah\u00e9 k\u00e1ble. Odpove\u010f si vy\u017eaduje, aby sme sa zamysleli nad t\u00fdm, \u010do slovo \u201cdestrukt\u00edvny\u201d skuto\u010dne znamen\u00e1. Testovanie VLF je \u201csk\u00fa\u0161ka odolnosti\u201d. To znamen\u00e1, \u017ee na k\u00e1bel p\u00f4sob\u00edme vysok\u00fdm nap\u00e4t\u00edm po\u010das ur\u010dit\u00e9ho \u010dasu. Zvy\u010dajne pou\u017e\u00edvame trojn\u00e1sobok be\u017en\u00e9ho prev\u00e1dzkov\u00e9ho nap\u00e4tia.<\/p><p> <\/p><p>Ak je k\u00e1bel v perfektnom stave, t\u00fato z\u00e1\u0165a\u017e bez probl\u00e9mov vydr\u017e\u00ed. Plastov\u00e1 izol\u00e1cia nebude starn\u00fa\u0165 r\u00fdchlej\u0161ie. K\u00e1bel sa neroztav\u00ed. K\u00e1bel zostane \u00faplne bezpe\u010dn\u00fd. Na skuto\u010dn\u00fdch stavenisk\u00e1ch sa v\u0161ak st\u00e1vaj\u00fa chyby. Pracovn\u00edk urob\u00ed chybu pri sp\u00e1jan\u00ed dvoch k\u00e1blov. Toto spojenie sa stane slab\u00fdm miestom. Po\u010das in\u0161tal\u00e1cie sa do k\u00e1bla dostane ne\u010distota alebo voda. Izol\u00e1cia sa oslab\u00ed. Ke\u010f pripoj\u00edme VLF nap\u00e4tie, pr\u00edstroj toto slab\u00e9 miesto odhal\u00ed. Nap\u00e4tie sp\u00f4sob\u00ed zlyhanie po\u0161koden\u00e9ho spoja. K\u00e1bel sa po\u010das testu po\u0161kod\u00ed. Je to zl\u00e9? Nie. Je to ve\u013emi dobr\u00e9. Chcete, aby sa k\u00e1bel preru\u0161il po\u010das testovania na pr\u00e1zdnom stavenisku. Nechcete, aby explodoval o tri mesiace nesk\u00f4r. Neskor\u0161ia expl\u00f3zia m\u00f4\u017ee zni\u010di\u0165 tov\u00e1re\u0148.<\/p><h3 class=\"wp-block-heading\">Skuto\u010dn\u00fd pr\u00edbeh zo Saudskej Ar\u00e1bie<\/h3><p>Minul\u00fd rok si dod\u00e1vate\u013e EPC v Saudskej Ar\u00e1bii zak\u00fapil VLF tester. In\u0161talovali 5-kilometrov\u00fd k\u00e1bel s nap\u00e4t\u00edm 33 kV pre nov\u00fa sol\u00e1rnu farmu. Projektov\u00fd mana\u017e\u00e9r sa b\u00e1l tento k\u00e1bel otestova\u0165. Domnieval sa, \u017ee vysok\u00e9 nap\u00e4tie by mohol cel\u00fd k\u00e1bel zni\u010di\u0165. Vysvetlil som mu fyzik\u00e1lne princ\u00edpy VLF met\u00f3dy. Test vykonali. Test zlyhal v 15. min\u00fate. Mana\u017e\u00e9r bol nahnevan\u00fd. Zavolal mi. Tvrdil, \u017ee m\u00f4j pr\u00edstroj zni\u010dil jeho nov\u00fd k\u00e1bel. Poradil som mu, aby zistil presn\u00e9 miesto poruchy. Pou\u017eili lokaliz\u00e1tor por\u00fach k\u00e1blov. Vykopali zem. Na\u0161li hlbok\u00fd rez v izol\u00e1cii k\u00e1bla. Neopatrn\u00fd pracovn\u00edk pred zakopan\u00edm k\u00e1bla na\u0148 upustil n\u00e1radie. N\u00e1\u0161 pr\u00edstroj nezni\u010dil dobr\u00fd k\u00e1bel. N\u00e1\u0161 pr\u00edstroj odhalil skryt\u00e9 nebezpe\u010denstvo. Zni\u010dil po\u0161koden\u00fd \u00fasek sk\u00f4r, ako mohol sp\u00f4sobi\u0165 ve\u013ek\u00fa katastrofu. Opravili ten mal\u00fd \u00fasek. Znovu to otestovali. Test pre\u0161iel.<\/p><figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"643\" src=\"https:\/\/kvhipot.com\/wp-content\/uploads\/2026\/03\/Middle-East-Substation_-1024x643.jpg\" alt=\"\" class=\"wp-image-6391\" srcset=\"https:\/\/kvhipot.com\/wp-content\/uploads\/2026\/03\/Middle-East-Substation_-1024x643.jpg 1024w, https:\/\/kvhipot.com\/wp-content\/uploads\/2026\/03\/Middle-East-Substation_-700x440.jpg 700w, https:\/\/kvhipot.com\/wp-content\/uploads\/2026\/03\/Middle-East-Substation_-768x483.jpg 768w, https:\/\/kvhipot.com\/wp-content\/uploads\/2026\/03\/Middle-East-Substation_-18x12.jpg 18w, https:\/\/kvhipot.com\/wp-content\/uploads\/2026\/03\/Middle-East-Substation_.jpg 1165w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><h3 class=\"wp-block-heading\">Ako spolo\u010dnos\u0165 VLF chr\u00e1ni va\u0161u invest\u00edciu<\/h3><p>V\u00fdsledky testu VLF m\u00f4\u017eeme posudzova\u0165 jednoduch\u00fdm sp\u00f4sobom. To n\u00e1m pom\u00e1ha pochopi\u0165 jeho skuto\u010dn\u00fa hodnotu.<\/p><figure class=\"wp-block-table\"><table><thead><tr><th>Stav k\u00e1bla<\/th><th>V\u00fdsledok testu<\/th><th>Skuto\u010dn\u00e9 v\u00fdsledky v praxi<\/th><\/tr><\/thead><tbody><tr><td><strong>Zdrav\u00fd k\u00e1bel<\/strong><\/td><td>Spl\u0148uje 60-min\u00fatov\u00fd test.<\/td><td>Bezpe\u010dne funguje u\u017e 30 rokov. Test nesp\u00f4sobil \u017eiadne po\u0161kodenie.<\/td><\/tr><tr><td><strong>Prerez v izol\u00e1cii<\/strong><\/td><td>Po\u010das testu do\u0161lo k zlyhaniu.<\/td><td>Toto po\u0161koden\u00e9 miesto m\u00f4\u017eete opravi\u0165 hne\u010f teraz za n\u00edzku cenu.<\/td><\/tr><tr><td><strong>Voda vo vn\u00fatri spoja<\/strong><\/td><td>Okam\u017eite zlyh\u00e1.<\/td><td>Spoj vyme\u0148te e\u0161te predt\u00fdm, ako ho zakopete do zeme.<\/td><\/tr><tr><td><strong>V\u00f4bec nebolo testovan\u00e9<\/strong><\/td><td>Nezn\u00e1my stav.<\/td><td>Nesk\u00f4r vybuchne. Jeho vykopanie a oprava stoj\u00ed obrovsk\u00e9 peniaze.<\/td><\/tr><\/tbody><\/table><\/figure><p>Preto m\u00e1 VLF de\u0161trukt\u00edvny vplyv iba na skryt\u00e9 probl\u00e9my. Funguje ako pr\u00edsny kontrol\u00f3r kvality va\u0161ej elektrickej siete. Ne\u0161kod\u00ed funk\u010dn\u00e9mu zariadeniu.<\/p><h2 class=\"wp-block-heading\">Pre\u010do pri testovan\u00ed vysokonap\u00e4\u0165ov\u00fdch k\u00e1blov pou\u017e\u00edvame iba ve\u013emi n\u00edzke frekvencie (VLF) a nie stredn\u00e9 alebo vysok\u00e9 frekvencie?<\/h2><p>Preprava \u0165a\u017ek\u00fdch testovac\u00edch zariaden\u00ed na vzdialen\u00e9 miesta je no\u010dn\u00e1 mora. Vysokofrekven\u010dn\u00e9 striedav\u00e9 testery s\u00fa na pou\u017eitie v ter\u00e9ne pr\u00edli\u0161 ve\u013ek\u00e9 a \u0165a\u017ek\u00e9. Frekvencia VLF tento probl\u00e9m s obrovskou hmotnos\u0165ou okam\u017eite rie\u0161i.\u00a0<strong>Pou\u017e\u00edvame ve\u013emi n\u00edzku frekvenciu (0,1 Hz), preto\u017ee t\u00e1to met\u00f3da vy\u017eaduje 600-kr\u00e1t menej energie ako \u0161tandardn\u00e1 sk\u00fa\u0161ka pri 60 Hz. V\u010faka tomu m\u00f4\u017ee by\u0165 sk\u00fa\u0161obn\u00fd pr\u00edstroj mal\u00fd, \u013eahk\u00fd a prenosn\u00fd. To umo\u017e\u0148uje vykon\u00e1va\u0165 ter\u00e9nne sk\u00fa\u0161ky dlh\u00fdch vysokonap\u00e4\u0165ov\u00fdch k\u00e1blov.<\/strong>\u00a0<\/p><p>\u00a0Aby sme pochopili, pre\u010do pou\u017e\u00edvame frekvenciu 0,1 Hz, mus\u00edme si vysvetli\u0165, ako funguje nap\u00e1jac\u00ed k\u00e1bel. Dlh\u00fd nap\u00e1jac\u00ed k\u00e1bel nie je len oby\u010dajn\u00fd vodi\u010d. Funguje presne ako obrovsk\u00fd kondenz\u00e1tor. Kondenz\u00e1tor je elektrick\u00e1 s\u00fa\u010diastka, ktor\u00e1 uklad\u00e1 energiu. \u010c\u00edm je k\u00e1bel dlh\u0161\u00ed, t\u00fdm viac energie uklad\u00e1. \u010c\u00edm vy\u0161\u0161ie je nap\u00e4tie, t\u00fdm viac energie uklad\u00e1. Ke\u010f testujete k\u00e1bel striedav\u00fdm pr\u00fadom (AC), mus\u00edte do tohto obrovsk\u00e9ho kondenz\u00e1tora vtla\u010di\u0165 energiu. Vtla\u010d\u00edte energiu dovn\u00fatra. Potom ju z neho vytiahnete. Rob\u00edte to mnohokr\u00e1t za sekundu.<div style=\"position: absolute; top: 138px; left: 68px; z-index: 1000; cursor: pointer; opacity: 1; transition: opacity 200ms; width: 24px; height: 24px;\"><svg viewbox=\"0 0 54 54\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><title>Prida\u0165 do doplnkov programu Photoshop<\/title><path d=\"M44.26 0H9.74C4.36075 0 0 4.36075 0 9.74V44.26C0 49.6393 4.36075 54 9.74 54H44.26C49.6393 54 54 49.6393 54 44.26V9.74C54 4.36075 49.6393 0 44.26 0Z\" fill=\"#001E36\"><\/path><path d=\"M18.7398 14.4297C25.7698 14.4297 29.7298 17.7197 29.7298 23.2397C29.7298 29.6797 24.3598 32.2697 19.3298 32.2697H15.9298V39.2297H9.0498V14.4297H18.7498H18.7398ZM15.9298 20.3097V26.3797H18.9598C21.0698 26.3797 22.5498 25.5297 22.5498 23.3797C22.5498 21.4197 21.2898 20.3097 19.1098 20.3097H15.9298Z\" fill=\"#31A8FF\"><\/path><path d=\"M31.4299 37.9995L31.4699 32.2595C33.4299 33.5595 36.1699 34.3695 38.0599 34.3695C39.3499 34.3695 39.9499 33.9995 39.9499 33.3295C39.9499 32.5895 39.1399 32.2895 37.5799 31.8095C34.5799 30.9195 31.2899 29.6995 31.2899 25.7795C31.2899 21.8595 34.5799 19.5595 39.3599 19.5595C41.6199 19.5595 43.4699 19.8895 45.0999 20.5995L45.0599 26.0795C43.7699 25.2995 41.2099 24.5995 39.5499 24.5995C38.3299 24.5995 37.8499 24.9695 37.8499 25.5295C37.8499 26.1995 38.4399 26.3795 40.2199 26.9395C43.6599 27.9795 46.5499 29.0895 46.5499 33.1195C46.5499 37.1495 43.3999 39.5595 38.4799 39.5595C35.8899 39.5595 33.4499 39.1195 31.4499 38.0095L31.4299 37.9995Z\" fill=\"#31A8FF\"><\/path><\/svg><\/div><\/p><h3 class=\"wp-block-heading\">Probl\u00e9m s frekvenciou 50 Hz alebo 60 Hz<\/h3><p>Ak pou\u017e\u00edvate be\u017en\u00fa sie\u0165ov\u00fa frekvenciu, napr\u00edklad 50 Hz alebo 60 Hz, mus\u00edte ka\u017ed\u00fa sekundu 50-kr\u00e1t alebo 60-kr\u00e1t \u201etla\u010di\u0165\u201c a \u201e\u0165aha\u0165\u201c. Vysielanie vysok\u00e9ho nap\u00e4tia do dlh\u00e9ho k\u00e1bla 50-kr\u00e1t za sekundu je ve\u013emi n\u00e1ro\u010dn\u00e1 \u00faloha. Vy\u017eaduje si obrovsk\u00e9 mno\u017estvo elektrick\u00e9ho pr\u00fadu. Na dodanie tohto obrovsk\u00e9ho pr\u00fadu potrebujete obrovsk\u00fd testovac\u00ed pr\u00edstroj. Ak chcete otestova\u0165 10-kilometrov\u00fd k\u00e1bel s nap\u00e4t\u00edm 33 kV pri frekvencii 50 Hz, v\u00e1\u0161 testovac\u00ed pr\u00edstroj by mal ve\u013ekos\u0165 ve\u013ek\u00e9ho prepravn\u00e9ho kontajnera. V\u00e1\u017eil by tis\u00edce kilogramov. Na jeho presun by ste potrebovali ve\u013ek\u00fd n\u00e1kladn\u00fd automobil. Na jeho zdvihnutie by ste potrebovali \u017eeriav. Pre mojich klientov je to nemo\u017en\u00e9. Moji klienti pracuj\u00fa v p\u00fa\u0161ti. Pracuj\u00fa v hor\u00e1ch. Pracuj\u00fa na preplnen\u00fdch mestsk\u00fdch uliciach. Nem\u00f4\u017eu si na ka\u017ed\u00e9 testovacie miesto priviez\u0165 \u017eeriav.<\/p><h3 class=\"wp-block-heading\">K\u00fazlo 0,1 Hz<\/h3><p>Tu n\u00e1m pom\u00f4\u017ee jednoduch\u00e1 matematika. Existuje z\u00e1kladn\u00fd elektrotechnick\u00fd z\u00e1kon. Potrebn\u00fd pr\u00fad priamo s\u00favis\u00ed s frekvenciou. Ak zn\u00ed\u017eite frekvenciu, zn\u00ed\u017eite aj pr\u00fad. Ak zmen\u00edme frekvenciu z 60 Hz na 0,1 Hz, zn\u00ed\u017eime ju 600-n\u00e1sobne. Ke\u010f\u017ee je frekvencia 600-kr\u00e1t men\u0161ia, pr\u00fad, ktor\u00fd potrebujeme, je tie\u017e 600-kr\u00e1t men\u0161\u00ed. V\u00fdkon, ktor\u00fd potrebujeme, je 600-kr\u00e1t men\u0161\u00ed. Ke\u010f\u017ee potrebujeme menej v\u00fdkonu, m\u00f4\u017eeme postavi\u0165 ove\u013ea men\u0161\u00ed stroj.<\/p><h3 class=\"wp-block-heading\">Skuto\u010dn\u00fd pr\u00edbeh z Vietnamu<\/h3><p>M\u00e1m klienta vo Vietname. Zaoberaj\u00fa sa elektrick\u00fdmi slu\u017ebami pre vetern\u00e9 elektr\u00e1rne. Pred p\u00e1r rokmi pou\u017e\u00edvali obrovsk\u00fd rezonan\u010dn\u00fd testovac\u00ed syst\u00e9m na striedav\u00fd pr\u00fad. Potrebovali otestova\u0165 k\u00e1bel na vrchole hory. N\u00e1kladn\u00e9 auto sa nedok\u00e1zalo vyjs\u0165 po po\u013enej ceste. Museli pr\u00e1cu preru\u0161i\u0165. Zavolali mi o pomoc. Predal som im tester KV HIPOT VLF. Pr\u00edstroj VLF m\u00e1 ve\u013ekos\u0165 ve\u013ek\u00e9ho kufra. Dvaja in\u017einieri ho nalo\u017eili do zadnej \u010dasti mal\u00e9ho d\u017e\u00edpu. Vy\u0161li s n\u00edm na horu. Dvaja mu\u017ei ho odniesli ku k\u00e1blu. Pr\u00e1cu dokon\u010dili za jednu hodinu.<\/p><figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/kvhipot.com\/wp-content\/uploads\/2025\/08\/VLF-Testings.jpg\" alt=\"\" class=\"wp-image-6239\" style=\"width:378px;height:auto\" srcset=\"https:\/\/kvhipot.com\/wp-content\/uploads\/2025\/08\/VLF-Testings.jpg 800w, https:\/\/kvhipot.com\/wp-content\/uploads\/2025\/08\/VLF-Testings-700x700.jpg 700w, https:\/\/kvhipot.com\/wp-content\/uploads\/2025\/08\/VLF-Testings-500x500.jpg 500w, https:\/\/kvhipot.com\/wp-content\/uploads\/2025\/08\/VLF-Testings-768x768.jpg 768w, https:\/\/kvhipot.com\/wp-content\/uploads\/2025\/08\/VLF-Testings-12x12.jpg 12w, https:\/\/kvhipot.com\/wp-content\/uploads\/2025\/08\/VLF-Testings-600x600.jpg 600w, https:\/\/kvhipot.com\/wp-content\/uploads\/2025\/08\/VLF-Testings-100x100.jpg 100w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure><h3 class=\"wp-block-heading\">Pre\u010do nie vysokofrekven\u010dn\u00e9?<\/h3><p>Niektor\u00ed \u013eudia sa p\u00fdtaj\u00fa na vysok\u00fa frekvenciu. Ak pri 60 Hz potrebujete zariadenie ve\u013ek\u00e9 ako n\u00e1kladn\u00e9 auto, predstavte si vysok\u00fa frekvenciu, napr\u00edklad 1000 Hz. Zariadenie by muselo ma\u0165 rozmery elektr\u00e1rne. Je fyzicky nemo\u017en\u00e9 testova\u0165 dlh\u00e9 k\u00e1ble s vysokou frekvenciou v ter\u00e9ne. Tu je jednoduch\u00e1 tabu\u013eka, ktor\u00e1 ukazuje, pre\u010do je 0,1 Hz jedinou skuto\u010dnou vo\u013ebou.<\/p><figure class=\"wp-block-table\"><table><thead><tr><th>Typ frekvencie<\/th><th>Pr\u00edklad<\/th><th>Ve\u013ekos\u0165 stroja<\/th><th>D\u00e1 sa to \u013eahko presun\u00fa\u0165?<\/th><\/tr><\/thead><tbody><tr><td><strong>Vysok\u00e1 frekvencia<\/strong><\/td><td>1000 Hz<\/td><td>Ve\u013ekos\u0165 budovy<\/td><td>Nie. To nie je mo\u017en\u00e9.<\/td><\/tr><tr><td><strong>Be\u017en\u00e1 elektrick\u00e1 sie\u0165<\/strong><\/td><td>50 Hz \/ 60 Hz<\/td><td>Ve\u013ekos\u0165 ve\u013ek\u00e9ho n\u00e1kladn\u00e9ho vozidla<\/td><td>Ve\u013emi \u0165a\u017ek\u00e9. Bude potrebn\u00fd \u017eeriav.<\/td><\/tr><tr><td><strong>Ve\u013emi n\u00edzka frekvencia<\/strong><\/td><td>0,1 Hz<\/td><td>Ve\u013ekos\u0165 kufra<\/td><td>\u00c1no. Dvaja mu\u017ei to dok\u00e1\u017eu unies\u0165.<\/td><\/tr><\/tbody><\/table><\/figure><p>V\u010faka frekvencii 0,1 Hz v\u00e1m na\u0161e testovacie zariadenia poskytuj\u00fa presne rovnak\u00fa kvalitu testovania striedav\u00e9ho pr\u00fadu. Z\u00e1rove\u0148 sa v\u0161ak zmestia do malej krabi\u010dky. V\u010faka tomu je testovanie v ter\u00e9ne r\u00fdchle, lacn\u00e9 a mo\u017en\u00e9 kdeko\u013evek na svete.<\/p><h2 class=\"wp-block-heading\">M\u00f4\u017ee tester k\u00e1blov VLF pracova\u0165 s frekvenciou 0,1 Hz alebo 0,01 Hz?<\/h2><p>V\u00fdber nespr\u00e1vnej frekvencie v\u00e1m m\u00f4\u017ee pokazi\u0165 cel\u00fd de\u0148. Pomal\u00fd test v\u00e1s stoj\u00ed peniaze aj \u010das. Ak pochop\u00edte rozdiel medzi 0,1 Hz a 0,01 Hz, u\u0161etr\u00edte si hodiny pr\u00e1ce.\u00a0<strong>\u00c1no, ak m\u00e1te ve\u013emi dlh\u00fd k\u00e1bel, m\u00f4\u017eete pou\u017ei\u0165 frekvenciu 0,01 Hz. Test pri frekvencii 0,01 Hz v\u0161ak trv\u00e1 ove\u013ea dlh\u0161ie ako test pri frekvencii 0,1 Hz. Frekvenciu 0,01 Hz by ste mali pou\u017ei\u0165 len vtedy, ak d\u013a\u017eka k\u00e1bla pri frekvencii 0,1 Hz prekra\u010duje v\u00fdkonov\u00fd limit zariadenia.<\/strong>\u00a0\u00a0<\/p><p>Ke\u010f sa pozriete na obrazovku <strong>KV HIPOT<\/strong> Na VLF testeru sa zobrazuj\u00fa r\u00f4zne mo\u017enosti frekvencie. Zvy\u010dajne s\u00fa to 0,1 Hz, 0,05 Hz, 0,02 Hz a 0,01 Hz. Mnoh\u00ed in\u017einieri nevedia, ktor\u00fa z nich si maj\u00fa vybra\u0165. Domnievaj\u00fa sa, \u017ee v\u0161etky hodnoty ved\u00fa k rovnak\u00e9mu v\u00fdsledku. To je ve\u013ek\u00e1 chyba. Medzin\u00e1rodn\u00fdm \u0161tandardom pre testovanie VLF je 0,1 Hz. V\u017edy by ste sa mali najsk\u00f4r pok\u00fasi\u0165 pou\u017ei\u0165 0,1 Hz. Niekedy to v\u0161ak nie je mo\u017en\u00e9.<\/p><h3 class=\"wp-block-heading\">Hranice stroja<\/h3><p>Ka\u017ed\u00fd testovac\u00ed pr\u00edstroj m\u00e1 svoje obmedzenie. Toto obmedzenie z\u00e1vis\u00ed od d\u013a\u017eky k\u00e1bla. T\u00fato d\u013a\u017eku meriame ako \u201ckapacitu\u201d. Ve\u013emi dlh\u00fd k\u00e1bel m\u00e1 ve\u013emi vysok\u00fa kapacitu. Ak pripoj\u00edte VLF tester k 15-kilometrov\u00e9mu k\u00e1blu a stla\u010d\u00edte tla\u010didlo \u0161tart pri frekvencii 0,1 Hz, pr\u00edstroj m\u00f4\u017ee vyd\u00e1va\u0165 p\u00edpanie. Na displeji sa m\u00f4\u017ee zobrazi\u0165 hl\u00e1senie \u201cPre\u0165a\u017eenie\u201d alebo \u201cPr\u00edli\u0161 vysok\u00e1 kapacita\u201d. Pr\u00edstroj nem\u00e1 dostato\u010dn\u00fd v\u00fdkon na to, aby do tak\u00e9ho obrovsk\u00e9ho k\u00e1bla dod\u00e1val nap\u00e4tie 0,1-kr\u00e1t za sekundu. Preto v\u00e1m pon\u00fakame mo\u017enos\u0165 zmeni\u0165 frekvenciu na 0,01 Hz. Ak zn\u00ed\u017eite frekvenciu desa\u0165n\u00e1sobne, pr\u00edstroj potrebuje desa\u0165n\u00e1sobne menej energie. Pr\u00edstroj teraz m\u00f4\u017ee bez probl\u00e9mov otestova\u0165 aj ten obrovsk\u00fd 20-kilometrov\u00fd k\u00e1bel.<\/p><h3 class=\"wp-block-heading\">Skryt\u00fd probl\u00e9m s frekvenciou 0,01 Hz<\/h3><p>Ak frekvencia 0,01 Hz zvy\u0161uje v\u00fdkonnos\u0165 zariadenia, pre\u010do ju nepou\u017e\u00edvame neust\u00e1le? Odpove\u010fou je \u010das. Technol\u00f3gia VLF vyu\u017e\u00edva striedav\u00fd pr\u00fad. Nap\u00e4tie st\u00fapa a kles\u00e1, \u010d\u00edm vznik\u00e1 vlna. Pri frekvencii 0,1 Hz trv\u00e1 jeden kompletn\u00fd cyklus 10 sek\u00fand. Pri be\u017enom 30-min\u00fatovom teste prejde k\u00e1blom 180 cyklov. To je dostato\u010dn\u00fd po\u010det cyklov na zistenie slab\u00e9ho miesta. Pri frekvencii 0,01 Hz je vlna ve\u013emi pomal\u00e1. Jedna kompletn\u00e1 vlna trv\u00e1 100 sek\u00fand. Po\u010das 30-min\u00fatov\u00e9ho testu prejde k\u00e1blom len 18 v\u013an. To je ve\u013emi mal\u00fd po\u010det. Na rozbitie po\u0161koden\u00e9ho spoja to nemus\u00ed sta\u010di\u0165.<\/p><h3 class=\"wp-block-heading\">Dodr\u017eiavanie pravidiel<\/h3><p>Norma IEEE 400.2 presne stanovuje, ako postupova\u0165. Ak zn\u00ed\u017eite frekvenciu, mus\u00edte pred\u013a\u017ei\u0165 dobu testovania. K\u00e1bel mus\u00ed by\u0165 vystaven\u00fd dostato\u010dn\u00e9mu po\u010dtu vlnen\u00ed, aby bolo mo\u017en\u00e9 odhali\u0165 skryt\u00e9 poruchy. Ak testujete pri frekvencii 0,1 Hz, testovanie m\u00f4\u017ee trva\u0165 30 min\u00fat. Ak prejdete na frekvenciu 0,05 Hz, testovanie m\u00f4\u017ee trva\u0165 a\u017e 60 min\u00fat. Ak prejdete na frekvenciu 0,01 Hz, testovanie m\u00f4\u017ee trva\u0165 mnoho hod\u00edn.<\/p><h3 class=\"wp-block-heading\">Skuto\u010dn\u00fd pr\u00edbeh z Ju\u017enej Afriky<\/h3><p>Pom\u00e1hal som dod\u00e1vate\u013eovi EPC v Ju\u017enej Afrike. Stavali obrovsk\u00fa sol\u00e1rnu farmu. Museli otestova\u0165 hlavn\u00fd nap\u00e1jac\u00ed k\u00e1bel. Mal d\u013a\u017eku 12 kilometrov. Pripojili tester VLF. Nastavili ho na 0,1 Hz. Pr\u00edstroj signalizoval chybu pre\u0165a\u017eenia. Zavolali mi cez WhatsApp. Boli v strese. In\u0161pektor u\u017e \u010dakal. Poradil som im, aby zmenili frekvenciu na 0,05 Hz. Sk\u00fasili to. St\u00e1le sa zobrazovala chyba. K\u00e1bel bol pr\u00edli\u0161 ve\u013ek\u00fd. Poradil som im, aby ju zmenili na 0,02 Hz. Stla\u010dili tla\u010didlo \u0161tart. Pr\u00edstroj fungoval bezchybne. Nap\u00e4tie st\u00faplo. Ale varoval som ich. Povedal som: \u201cTeraz nem\u00f4\u017eete urobi\u0165 15-min\u00fatov\u00fd test. Frekvencia je pr\u00edli\u0161 n\u00edzka. Test mus\u00edte spusti\u0165 na dlh\u0161\u00ed \u010das.\u201d Povedali to in\u0161pektorovi. In\u0161pektor s\u00fahlasil. Test spustili na dlh\u0161\u00ed \u010das. K\u00e1bel pre\u0161iel. Dostali zaplaten\u00e9. Tu je jednoduch\u00e1 tabu\u013eka, ktor\u00e1 v\u00e1m pom\u00f4\u017ee vybra\u0165 spr\u00e1vnu frekvenciu priamo na mieste.<\/p><figure class=\"wp-block-table\"><table><thead><tr><th>Nastavenie frekvencie<\/th><th>\u010cas na jednu vlnu<\/th><th>Najvhodnej\u0161ie pou\u017eitie<\/th><th>Upozornenie<\/th><\/tr><\/thead><tbody><tr><td><strong>0,1 Hz<\/strong><\/td><td>10 sek\u00fand<\/td><td>Be\u017en\u00e9 k\u00e1ble. Kr\u00e1tke k\u00e1ble. \u0160tandardn\u00e1 sk\u00fa\u0161ka.<\/td><td>V\u017edy to najprv vysk\u00fa\u0161ajte.<\/td><\/tr><tr><td><strong>0,05 Hz<\/strong><\/td><td>20 sek\u00fand<\/td><td>Stredne dlh\u00e9 a dlh\u00e9 k\u00e1ble.<\/td><td>Dokon\u010denie testu trv\u00e1 dlh\u0161ie.<\/td><\/tr><tr><td><strong>0,02 Hz<\/strong><\/td><td>50 sek\u00fand<\/td><td>Ve\u013emi dlh\u00e9 k\u00e1ble.<\/td><td>Je potrebn\u00e1 ove\u013ea dlh\u0161ia doba testovania.<\/td><\/tr><tr><td><strong>0,01 Hz<\/strong><\/td><td>100 sek\u00fand<\/td><td>Mimoriadne dlh\u00e9 k\u00e1ble.<\/td><td>Test m\u00f4\u017ee trva\u0165 nieko\u013eko hod\u00edn. Pou\u017e\u00edvajte len v pr\u00edpade potreby.<\/td><\/tr><\/tbody><\/table><\/figure><p>Je teda v poriadku pou\u017ei\u0165 frekvenciu 0,01 Hz? \u00c1no. Je to \u00faplne v poriadku. Pr\u00edstroj je na to navrhnut\u00fd. Mus\u00edte v\u0161ak ma\u0165 na pam\u00e4ti jedno pravidlo: ni\u017e\u0161ia frekvencia znamen\u00e1, \u017ee potrebujete dlh\u0161\u00ed \u010das testovania. V\u017edy za\u010dnite s frekvenciou 0,1 Hz. Na ni\u017e\u0161iu hodnotu prejdite a\u017e vtedy, ke\u010f v\u00e1m pr\u00edstroj ozn\u00e1mi, \u017ee k\u00e1bel je pr\u00edli\u0161 ve\u013ek\u00fd.<\/p><h2 class=\"wp-block-heading\">Z\u00e1ver<\/h2><p>Testovanie k\u00e1blov pomocou VLF je bezpe\u010dn\u00e1 a rozumn\u00e1 vo\u013eba pre va\u0161e k\u00e1ble. V\u00fdberom spr\u00e1vnej frekvencie \u013eahko odhal\u00edte skryt\u00e9 poruchy a zabezpe\u010d\u00edte bezchybn\u00fa prev\u00e1dzku va\u0161ej elektrickej siete.<\/p>","protected":false},"excerpt":{"rendered":"<p>Testovanie k\u00e1blov pomocou VLF je bezpe\u010dn\u00e1 a rozumn\u00e1 vo\u013eba pre va\u0161e k\u00e1ble. V\u00fdberom spr\u00e1vnej frekvencie \u013eahko odhal\u00edte skryt\u00e9 poruchy a zabezpe\u010d\u00edte bezchybn\u00fa prev\u00e1dzku va\u0161ej elektrickej siete.<\/p>","protected":false},"author":1,"featured_media":5754,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","footnotes":""},"categories":[35],"tags":[],"_links":{"self":[{"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/posts\/6420"}],"collection":[{"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/comments?post=6420"}],"version-history":[{"count":1,"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/posts\/6420\/revisions"}],"predecessor-version":[{"id":6423,"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/posts\/6420\/revisions\/6423"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/media\/5754"}],"wp:attachment":[{"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/media?parent=6420"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/categories?post=6420"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kvhipot.com\/sk\/wp-json\/wp\/v2\/tags?post=6420"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}