{"id":518,"date":"2022-09-25T19:21:04","date_gmt":"2022-09-25T11:21:04","guid":{"rendered":"https:\/\/kvhipot.com\/?post_type=product&#038;p=518"},"modified":"2022-09-25T19:21:04","modified_gmt":"2022-09-25T11:21:04","slug":"5kv-insulation-resistance-tester-kv3122","status":"publish","type":"product","link":"https:\/\/kvhipot.com\/ru\/product\/5kv-insulation-resistance-tester-kv3122\/","title":{"rendered":"\u0422\u0435\u0441\u0442\u0435\u0440 \u0441\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 5 \u043a\u0412 KV3122"},"content":{"rendered":"<p><strong><b>\u041e\u0431\u0437\u043e\u0440\u044b<\/b><\/strong><\/p>\n<p>KV3122 Insulation Resistance Tester\u00a0is suitable for measuring the resistance of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment. Digital insulation resistance meter is composed of medium and large scale integrated circuits, including high-precision micro current measurement system, digital boost system and automatic discharge circuit. Only a high voltage line and a signal line are needed to connect the measured the test object to measure.<\/p>\n<p>It can automatically calculate the absorption ratio(DAR) and polarization index(PI), and automatically store the data of 15 seconds, 30 seconds, 1 minute and 10 minutes.<\/p>\n<p>&nbsp;<\/p>\n<p><strong><b>Technical parameter <\/b><\/strong><\/p>\n<ol>\n<li><strong>Insulation Tester Measuring Range &amp; Accuracy<\/strong><\/li>\n<\/ol>\n<table>\n<tbody>\n<tr>\n<td width=\"289\"><strong>Output Volt<\/strong><\/td>\n<td width=\"178\"><strong>Test Range<\/strong><\/td>\n<td width=\"249\"><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"289\">250V\uff0815%\uff09DC<\/td>\n<td width=\"178\">0.01M\u03a9~2.50G\u03a9<\/td>\n<td width=\"249\">\u00b13%rdg\u00b15dgt<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">2.50G\u03a9~250\u00a0G\u03a9<\/td>\n<td width=\"249\">\u00b115%rdg\u00b15dgt<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"289\">500V\uff0810%\uff09DC<\/td>\n<td width=\"178\">0.01M\u03a9~5.00G\u03a9<\/td>\n<td width=\"249\">\u00b13%rdg\u00b15dgt<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">5.00G\u03a9~500\u00a0G\u03a9<\/td>\n<td width=\"249\">\u00b115%rdg\u00b15dgt<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"289\">1000V\uff0810%\uff09DC<\/td>\n<td width=\"178\">0.01M\u03a9~10.00G\u03a9<\/td>\n<td width=\"249\">\u00b13%rdg\u00b15dgt<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">10.00G\u03a9~1.00\u00a0T\u03a9<\/td>\n<td width=\"249\">\u00b115%rdg\u00b15dgt<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"289\">2500V\uff0810%\uff09DC<\/td>\n<td width=\"178\">0.01M\u03a9~25.0G\u03a9<\/td>\n<td width=\"249\">\u00b13%rdg\u00b15dgt<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">25.0G\u03a9~2.50\u00a0T\u03a9<\/td>\n<td width=\"249\">\u00b115%rdg\u00b15dgt<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"289\">5000V\uff0810%\uff09DC<\/td>\n<td width=\"178\">0.01M\u03a9~50.0G\u03a9<\/td>\n<td width=\"249\">\u00b13%rdg\u00b15dgt<\/td>\n<\/tr>\n<tr>\n<td width=\"178\">50.0G\u03a9~5.00\u00a0T\u03a9<\/td>\n<td width=\"249\">\u00b115%rdg\u00b15dgt<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ol start=\"2\">\n<li><strong>The range and accuracy for AC &amp; AC Voltage<\/strong><\/li>\n<\/ol>\n<table>\n<tbody>\n<tr>\n<td width=\"279\"><strong>Test Volt<\/strong><\/td>\n<td width=\"174\"><strong>Test Range<\/strong><\/td>\n<td width=\"251\"><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"279\">DC Voltage<\/td>\n<td width=\"174\">0.01V~1000V<\/td>\n<td width=\"251\">\u00b12%rdg\u00b13dgt<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>3\uff0e<\/strong><strong>General Specification<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"240\"><strong>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/strong><\/td>\n<td width=\"517\">Insulation resistance, polarization index, absorption ratio, AC and DC voltage test; automatic discharge function; environmental temperature test; clock function<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Power<\/strong><\/td>\n<td width=\"517\">DC 14.8V 2200mAh\u00a0rechargeable Li-Battery\uff0cfull battery volt approx. 16.8V<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong><b>\u041d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/b><\/strong><\/td>\n<td width=\"517\">Range\uff1a250V\u3001500V\u30011000V\u30012500V\u30015000V<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>\u0422\u0435\u043a\u0443\u0449\u0438\u0439<\/strong><\/td>\n<td width=\"517\">\u22655mA(\u226510mA\u3001\u22653.5mA\u3001\u22651.5mA\u00a0option)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"240\"><strong>Wire connection method<\/strong><\/td>\n<td width=\"517\">L\u00a0port\uff1a\u201cL&#8221;\u00a0called high voltage output port\uff0cIt is called the end of the line and leads to one end of the measured object<\/td>\n<\/tr>\n<tr>\n<td width=\"517\">G\u00a0port\uff1a&#8221;G&#8221;\u00a0called shield end, It is used to measure the insulation resistance of insulating materials or cables by three electrode method. It is connected to the end of electrode protection ring.<\/td>\n<\/tr>\n<tr>\n<td width=\"517\">E\u00a0port\uff1a&#8221;E&#8221;\u00a0called ground earth end\uff0cConnect to the ground and zero terminals of the measured object. For example, motor shell metal, transformer core, cable shield.<\/td>\n<\/tr>\n<tr>\n<td width=\"517\">V\u00a0port\uff1aAC \/ DC voltage measuring terminal\uff08AC \/ DC automatic identification\uff09<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"240\"><strong>Resolution<\/strong><\/td>\n<td width=\"517\">Insulation Resistance\uff1a0.01M\u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"517\">AC Voltage\uff1a0.01V<\/td>\n<\/tr>\n<tr>\n<td width=\"517\">DC Voltage\uff1a0.01V<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>\u0412\u0440\u0435\u043c\u044f \u0438\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u0439<\/strong><\/td>\n<td width=\"517\">1min~30min\uff08regarding method of test\uff0csettable)<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Backlight<\/strong><\/td>\n<td width=\"517\">Controllable white screen backlight, suitable for dark field<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong><b>Shift<\/b><\/strong><\/td>\n<td width=\"517\">Automatic shift<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong><b>LCD<\/b><\/strong><\/td>\n<td width=\"517\">4\u00a0bite LCD\u00a0display\uff0cwhite screen back light<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>LCD<\/strong><strong>\u00a0display size<\/strong><\/td>\n<td width=\"517\">124mm\u00d767mm<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Test display<\/strong><\/td>\n<td width=\"517\">In the measurement, the LED flashes and the progress bar chart indicates<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Charge display<\/strong><\/td>\n<td width=\"517\">When charging, the indicator light on the charger is red and green after full charge<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Size<\/strong><\/td>\n<td width=\"517\">Tester Size\uff1a(LWH)\u00a0258mm\u00d7215mm\u00d783mm<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Standard test lines<\/strong><\/td>\n<td width=\"517\">One red high voltage test rod, one green and one black test line<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Battery Voltage<\/strong><\/td>\n<td width=\"517\">Display the remaining power of the battery. When the battery is low, please charge it in time<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Communication port<\/strong><\/td>\n<td width=\"517\">With USB port, storage data upload to PC, save and print<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Telecommunication Lines<\/strong><\/td>\n<td width=\"517\">USB\u00a0line 1m, length 1.5m<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Working Current<\/strong><\/td>\n<td width=\"517\">Stand by\uff1a25mA Max(backlight off)\uff1bbacklight\uff1a25mA Max(only backlight on)\uff1bworking\uff1a450mA Max(backlight off)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"240\"><strong>\u0412\u0435\u0441<\/strong><\/td>\n<td width=\"517\">Instrument weight\uff1a2.19kg(within battery)<\/td>\n<\/tr>\n<tr>\n<td width=\"517\">Total weight\uff1a3.50kg(with package)<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Tool back<\/strong><\/td>\n<td width=\"517\">Yellow-Black double color toolbag\uff0ccarry conveniently\uff0cgood looking toolbag<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Working Humiture<\/strong><\/td>\n<td width=\"517\">-10\u2103\uff5e40\u2103\uff1b80%rh\u00a0below<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Storage Humiture<\/strong><\/td>\n<td width=\"517\">-20\u2103\uff5e60\u2103\uff1b70%rh\u00a0below<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Withstand voltage<\/strong><\/td>\n<td width=\"517\">AC 3700V\/rms(between outer shell two far points)<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>\u0421\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438<\/strong><\/td>\n<td width=\"517\">20M\u03a9\u00a0above (between bottom metal screw and top end 500V)<\/td>\n<\/tr>\n<tr>\n<td width=\"240\"><strong>Electromagnetic Characteristic<\/strong><\/td>\n<td width=\"517\">IEC61326(EMC)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Overviews KV3122 Insulation Resistance Tester\u00a0is suitable for measuring the resistance of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment. Digital insulation resistance meter is composed of medium and large scale integrated circuits, including high-precision micro current measurement system, digital boost system and automatic discharge circuit. Only a high voltage [&hellip;]<\/p>","protected":false},"featured_media":519,"template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":""},"product_cat":[27],"product_tag":[],"_links":{"self":[{"href":"https:\/\/kvhipot.com\/ru\/wp-json\/wp\/v2\/product\/518"}],"collection":[{"href":"https:\/\/kvhipot.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/kvhipot.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/kvhipot.com\/ru\/wp-json\/wp\/v2\/media\/519"}],"wp:attachment":[{"href":"https:\/\/kvhipot.com\/ru\/wp-json\/wp\/v2\/media?parent=518"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/kvhipot.com\/ru\/wp-json\/wp\/v2\/product_cat?post=518"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/kvhipot.com\/ru\/wp-json\/wp\/v2\/product_tag?post=518"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}